e-mail: [email protected]
Opening hours
Monday - Friday 9:00 a.m. - 5:00 p.m.
Saturday 9:00 a.m. - 13.00 p.m.
Product: | SOMMER CABLE - SC-BINARY 434 DMX512 cable |
---|---|
Brand: | Sommer |
Item number / Code: | 133763 / SOMMER-BINARY-434DMX |
Current availability: | 0 meter |
Note! The price of this product may have changed. Please contact our team to receive more information on the availability and price of this item. | |
Key words: | SOMMER CABLE - SC-BINARY 434 DMX512 cable, Sommer BINARY-434DMX, Sommer BINARY 434DMX, Sommer BINARY434DMX, BINARY-434DMX, BINARY 434DMX, BINARY434DMX |
Ask a Product Expert: | Filip Koperski, tel. +48 717974679, email: [email protected] |
SOMMER CABLE - SC-BINARY 434 DMX512
When data has to be passed back and forth, then a digital cable with a check-back channel should be used. The surge impedance for the Sommer SC-Binary 434 DMX512 cable is set at 110 Ohm. Two of the 4 wires are responsible for the check-back function. The robust outer jacket is suitable for outdoor and permanent installation. Due to the double shielding (AL/PT-foil + copper braiding) and wire coding it conforms with the generally applicable guidelines (VDE 0812/VDE 0207). Exellent for networking scanners and lighting units with feedback function, and as a connection of digital controls and various types of units.
Specifications:
• Digital transmission over long distances due to DMX- and AES/EBU-Standards
• Very good protection against electrical interference (copper braiding + AL/PT-foil)
• Extremely robust due to the special tough jacket
• Construction [2(2LI2YS0,34mm2)(ST)]CY
• Jacket, diameter PVC 7,0 mm
• AWG 22
• No. of inner conductors 4 x 0,34 mm2
• Copper strand per conductor 7 x 0,25 mm
• Conductor insulation PE 1,7 mm
• Shielding copper-cross mesh, tin-plated + AL/PT-foil
• Shielding factor 100 %
• Temperature range min. -25 °C
• Temperature range max. 70 °C
• Fire load per m 0,22 kWh
• Weight per 1 m 65 g
• Packaging 100 m roll
• Colour black
• Capac. cond./cond. per 1 m 65 pF
• Capac. cond./shield. per 1 m 245 pF
• Cond. resistance per 1 km 53 Ohm
• Shield. resistance per 1 km 15 Ohm
• Insulation resist. per 1 km > 5 GOhm
• Surge impedance 110 Ohm
• Transmission speed acc. to EIA 485 standard 256 Kbs